![]() The section view below details the requirements shown from the Australia Standards versus the Moddex Tuffrail TR25 system. AS 1657-2013 cites AS 1111.1-2000 ISO metric hexagon bolts and screws - Product grade C - Bolts. If a toeboard system is not required, then the maximum clear space between the lowest rail & the floor shall not exceed 560mm. A toeboard system, but only if there is no permanent structure within 10mm of the edge of a walkway or if an object could fall to where persons have access to the area below (see AS1657- 2018 Clause 5.5).One or more intermediate rails that are parallel with the top rail, spaced so that the maximum clear space between those rails does not exceed 450mm.10 years of industry experience Australian Standards (AS1657 & AS1891). ![]() ![]() A top rail parallel to the floor, or where used on a sloping walkway, parallel to the slope of the walkway, that is supported by posts at necessary intervals to meet the specified imposed actions. Our aluminium stairs are designed and manufactured to meet AS1657-2018. You may require this Standard if you work or employ people to work on a building or permanent structure, such as a platform, walkway, stairs or ladders. ![]() Under AS1657-2018 Clause 6.2.1.2, guardrails shall consist of: ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |